删除或更新信息,请邮件至freekaoyan#163.com(#换成@)

Influence of phase mismatching on temporal waveform of pulse in the process of frequency conversion_

上海光学精密机械研究所 免费考研网/2018-05-06

涓€鏉ザ鑼剁殑閽卞氨鍙互涔板埌鑰冪爺涓撲笟璇捐祫鏂欙紒
2涓囩鑰冪爺鐢靛瓙涔︼紙棰樺簱銆佽棰戙€佸叏濂楄祫鏂欙級鍙婂巻骞寸湡棰橈紝娑电洊547鎵€闄㈡牎4涓囦綑涓€冪爺鑰冨崥涓撲笟绉戠洰銆佽€冪爺鍏叡璇撅紙鏀挎不鑻辫鏁板锛夈€�40绉嶄笓涓氱澹紙閲戣瀺纭曞+銆丮BA銆佸浗闄呭晢鍔$澹€佹柊闂讳紶鎾澹€佺ぞ浼氬伐浣滅澹瓑锛夈€�28绫诲悓绛夊鍔涚敵纭曚笓涓氥€�1130绉嶇粡鍏告暀鏉愩€�
外文题目: Influence of phase mismatching on temporal waveform of pulse in the process of frequency conversion
作者: Cui, Zijian; Liu, Dean; Liu, Yaqun; Miao, Jie; Zhou, Shenlei; Zhu, Baoqiang; Zhu, Jianqiang
刊名: Proc.SPIE
来源图书: 2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: ADVANCED LASERS AND APPLICATIONS
年: 2015 卷: 9621 文章编号:962107
会议名称: International Conference on Optical Instruments and Technology - Advanced Lasers and Applications
英文关键词:
nonlinear optics; high power laser; frequency conversion; phase mismatching; temporal waveform; pulse width
EFFICIENT 3RD-HARMONIC GENERATION; PARTIALLY DEUTERATED KDP; BROAD-BAND; HARMONIC-GENERATION; PICOSECOND PULSES; CRYSTALS
英文摘要:
The influence of phase mismatching on output pulse temporal waveform in the process of second and third harmonic generation at various power densities with different detuning angles is studied based on nonlinear coupled-wave equations. The rules of different frequencies pulse width vary with the detuning angle have been analyzed quantitatively in potassium dihydrogen phosphate (KDP) crystals. The results of numerical simulation show that in high power laser frequency conversion system, the changes of fundamental pulse width are more sensitive to the detuning angle than second harmonic in the process of doubling, and the maximum variation of the full-width at half-maximum (FWHM) of fundamental at different detuning angles is about 19.0%. For tripling, the output pulse width changes of fundamental and second harmonic are sensitive to the detuning angle at high power density, and the maximum variation of their FWHM at different detuning angles are about 19.0% and 19.2%, respectively. However, the SH pulse width is almost unchanged at low power density. The results of this study may provide a promising route to determine the best angle for phase matching in the angle adjusting process of experiment.


文献类型: 会议论文
正文语种: English
收录类别: ISTP
DOI: 10.1117/12.2191489


全文传递服务
鎴愪负璇句唬琛紝鍒嗕韩璇剧▼璧勬枡閾炬帴灏辫兘鑾峰彇40%鎻愭垚璧氶挶锛�
鎺ㄥ箍璧氶挶鏉冪泭銆傝浠h〃鍙€氳繃浜掕仈缃戠瓑閫斿緞涓烘湰绔欐帹骞垮浼犫€淰IP浼氬憳鈥濓紝鐢ㄦ埛閫氳繃璇句唬琛ㄧ殑鍒嗕韩閾炬帴鎴栨捣鎶ヨ喘涔板悗锛岃浠h〃鑾峰彇40%鎻愭垚銆傝浠h〃璐拱鏈珯浠讳綍浜у搧锛屽潎浜彈9鎶樸€傚皢鍒嗕韩閾炬帴銆佹捣鎶ュ浘鐗囩瓑锛屽彂鍒板鏍¤鍧涖€佺櫨搴﹁创鍚с€佸井鍗氥€佸井淇°€丵Q绌洪棿銆佺煡涔庛€佽眴鐡g瓑鍚勫ぇ骞冲彴銆�
相关话题/英文 文献 外文 图书 论文