删除或更新信息,请邮件至freekaoyan#163.com(#换成@)

Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of S

上海光学精密机械研究所 免费考研网/2018-05-06

外文题目: Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance
作者: Liu, Chong; Ji, Lailin; Yang, Lin; Zhao, Dongfeng; Zhang, Yanfeng; Liu, Dong; Zhu, Baoqiang; Lin, Zunqi
刊名: Appl. Optics
年: 2016 卷: 55 期: 10 页: 2800--2812
英文关键词:

OMEGA LASER
英文摘要:
In order to obtain the intensity distribution of a 351 nm focal spot and smoothing by spectral dispersion (SSD) focal plane profile of a SGII-upgraded facility, a type of off-axis imaging system with three spherical mirrors, suitable for a finite distance source point to be imaged near the diffraction limit has been designed. The quality factor of the image system is 1.6 times of the diffraction limit tested by a 1053 nm point source. Because of the absence of a 351 nm point source, we can use a Collins diffraction imaging integral with respect to lambda = 351 nm, corresponding to a quality factor that is 3.8 times the diffraction limit at 351 nm. The calibration results show that at least the range of +/- 10 mrad of view field angle and +/- 50 mm along the axial direction around the optimum object distance can be satisfied with near diffraction limited image that is consistent with the design value. Using this image system, the No. 2 beam of the SGII-upgraded facility has been tested. The test result of the focal spot of final optics assembly (FOA) at 351 nm indicates that about 80% of energy is encompassed in 14.1 times the diffraction limit, while the output energy of the No. 2 beam is 908 J at 1053 nm. According to convolution theorem, the true value of a 351 nm focal spot of FOA is about 12 times the diffraction limit because of the influence of the quality factor. Further experimental studies indicate that the RMS value along the smoothing direction is less than 15.98% in the SSD spot test experiment. Computer simulations show that the quality factor of the image system used in the experiment has almost no effect on the SSD focal spot test. The image system can remarkably distort the SSD focal spot distribution under the circumstance of the quality factor 15 times worse than the diffraction limit. The distorted image shows a steep slope in the contour of the SSD focal spot along the smoothing direction that otherwise has a relatively flat top region around the focal spot center. (C) 2016 Optical Society of America


文献类型: 期刊论文
正文语种: English
收录类别: SCIEI
DOI: 10.1364/AO.55.002800


全文传递服务
相关话题/英文 文献 外文 语种 题目