HTML
--> --> -->During 12-18 May 2014, the scan profile of the FY-3C MWTS-2 was changed. Before this scan profile change, each scan cycle took 2.67 seconds. The antenna of the MWTS-2 scans at cold space, a warm target, and the earth scene with the same integration time of 0.018 s and accelerates during the time in between. After the profile change, the MWTS-2 kept a constant speed during each entire scan cycle of 5.23 s. MWTS-2 data from 5-11 March 2014 and 29 May to 4 June 2014 are used in this study. There are 14-15 swaths in a single day. Each swath contains around 2400 and 1200 scan lines before and after the scan profile change, respectively.
Numerous previous studies have demonstrated the significance of observations from temperature sounders such as the MWTS-2 and ATMS. (Tian and Zou, 2016) described an improved temperature retrieval algorithm for temperature sounder observations and applied the results to hurricane cases to analyze three-dimensional warm-core structures. (Tian and Zou, 2018) examined the temporal evolutions of thermal structures in the 2017 Hurricanes Harvey, Irma, and Maria using retrievals from temperature sounder observations. (Zou and Tian, 2018) developed a global positioning system radio occultation-based temperature retrieval algorithm with limb-corrected and remapped ATMS observations. As MWTS-2 has similar channel configurations, these recently proposed temperature retrieval algorithms are all readily applicable to MWTS-2 observations. There was a significant reduction in the random noise level in the results. Temperature sounder observations have also been shown to have positive impacts on hurricane track and intensity forecasts (Zou et al., 2013; Li et al., 2016; Li and Liu, 2016) as well as on global weather forecast skills (Eyre et al., 1993; Andersson et al., 1994; Derber and Wu, 1998). (Tian et al., 2018) showed that MWTS-2 observations, after limb correction, could be used to monitor tropical cyclones. The non-random, striping pattern noise found in ATMS observations may possibly be due to the 1/f noise in its receiver (Bormann et al., 2013; Qin et al., 2013). (Li et al., 2016) reported slightly higher analysis and forecast errors when assimilating MWTS-2 observations due to the striping noise. (Zou et al., 2017) described a principal component analysis (PCA) combined with Ensemble Empirical Mode Decomposition (EEMD) striping noise mitigation method for ATMS that is applicable to all temperature-sounding channels as well as window channels. Striping issues have also been found in the predecessors of MWTS-2, the MWTS onboard FY-3B, as well as the ATMS onboard the recently launched National Oceanic and Atmospheric Administration (NOAA-20) satellite (Li and Zou, 2015; Zou and Tian, 2019).
In this study, the PCA/EEMD striping noise mitigation is adopted and applied to MWTS-2 observations before and after the scan profile change to analyze the MWTS-2 striping noise characteristics. The same mitigation method can be readily applicable to other instruments, including the previous MWTS on previous FY-3 satellite series.
An EEMD method (Wu and Huang, 2009) can then be employed to remove the striping noise in the decomposed MWTS-2 observations, i.e., yk,i. The smoothed brightness temperature, $\bar{y}_{EEMD,k,i}$, can then be calculated by removing the first three intrinsic mode functions (IMFs) of the first PC, uk,1, as follows: \begin{equation} \label{eq3} \bar{y}_{{\rm EEMD},k,i}=e_{1,i}\left(u_{i,1}-\sum_{m=1}^3{\rm IMF}_m(k)\right)+\sum_{j=2}^{90}e_{j,i}u_{k,j} . \ \ (4)\end{equation}
The EEMD-smoothed PC coefficient can then be expressed as uEEMD,k,1=uk,1-∑m=1L IMFm(k), where L denotes the number of IMFs to be removed.
The spectra for the first six IMFs of the first four PC coefficients at channel 8 for 1 May 2014 are shown in Fig. 1. Peak magnitudes of the first four IMFs are at the frequencies greater than 10-2 Hz. The amplitude of an individual IMF decreases with PC coefficient sequence, i.e., all IMFs have the largest amplitudes for the first PC coefficient and the smallest amplitudes for the fourth PC coefficient. This is in accordance with the fact that the first PC component explains the majority of variances. The peak magnitudes of the IMFs of the first three PC coefficients start to increase noticeably after the fourth IMF. For example, the peak magnitudes of the fifth IMFs are ~10 times greater than the peak magnitudes of the first four IMFs. The absolute majority of the variances in observations from signals such as weather signals, instrument scan patterns, as well as striping noise are accounted for by the first three principal components (Qin et al., 2013; Zou et al., 2014). For the fourth PC coefficient, there is no clear difference in the peak magnitudes of the six IMFs. We thus choose to remove the first four IMFs of the first three PC coefficients, denoted as PC3/IMF4 for brevity. The distribution of the first five PC modes (i.e., eigenvectors) for the 47th MWTS-2 data sample (k=47, each sample includes 200 scan lines) on 1 May 2014 is displayed in Fig. 2. Note that the eigenvectors are functions of FOV positions. All PC modes oscillate around zero, and their values are close in scale. Compared with other PC modes, the first PC mode changes little. This is reasonable because the first PC mode represents the major cross-track scan features of the MWTS-2 while the other PC modes capture weather signals. The numbers of extrema for the second, third, fourth, and fifth PC modes are two, three, four, and five, respectively. Figure 3 shows the spatial distributions of the first, second, and third PC components, i.e., the products of PC coefficients and the corresponding PC modes. The magnitude of the first PC component is the greatest, comparable in magnitude to the brightness temperature. The second and third PC components have magnitudes of the same order. The PC components before and after smoothing are calculated as the PC coefficients with and without the first four IMFs removed, respectively. Before the noise mitigation, visible striping noise exists in all the three PC components. After smoothing, the striping noise is removed while large-scale features in the along-track and cross-track directions remain unchanged.
Figure1. Fourier spectra for the first six IMFs of the (a) first, (b) second, (c) third, and (d) fourth PC coefficients at channel 8 for MWTS-2 observations on 1 May 2014.
Figure2. Spatial distributions of the first five PC modes (i.e., eigenvectors) for the 47th MWTS-2 data sample (k=47, each sample includes 200 scan lines) on 1 May 2014.
Figure3. Spatial distributions of the first three PCA components (i.e., the product of an eigenvalue and an eigenvector) before (left panels) and after (right panels) striping noise mitigation for the 47th data sample (k=47, each sample includes 200 scan lines) on 1 May 2014.The Community Radiative Transfer Model is used in this study to simulate MWTS-2 brightness temperatures using the 6-h forecast field generated from the National Centers for Environmental Prediction Global Forecast System as the background. This was done to bring out the striping noise in observed brightness temperatures. The spatial distributions of the observed (O) and simulated (B) brightness temperatures on 1 May 2014 are displayed in Figs. 4a and b. The striping noise can be easily identified from the observed brightness temperature field. Figure 4c shows the spatial distribution after the PC3/IMF4 striping noise mitigation. Compared with Fig. 4a, no striping noise is found in the distribution of PC3/IMF4-smoothed brightness temperatures. The spatial distributions of the differences between observations and simulations (O-B) before and after the PC3/IMF4 noise mitigation are shown in Figs. 4e and f, respectively. The striping noise pattern clearly seen in Fig. 4e is effectively removed after PC3/IMF4 smoothing. Figure 5 shows the global distributions of (O-B) before and after the PC3/IMF4 striping noise mitigation on 1 May. It is clear that after smoothing, the visible striping noise is effectively removed while other weather-related features are not altered. The noise removed is shown in Fig. 5c.
Figure4. Spatial distributions of MWTS-2 channel 8 (a) observed, (b) simulated, and (c) smoothed brightness temperatures (units: K) for the 47th data sample (k=47, each sample includes 200 scan lines) on 1 May 2014. The first four IMFs of the first three PC coefficients are removed in (c). (d) Differences between (a) and (c). (e) Differences between (a) and (b). (f) Differences between (c) and (b).
Figure5. Global distributions of channel 8 (a) O-B and (b) differences between smoothed brightness temperatures removed on 1 May 2014 on the ascending node. The first four IMFs of the first three PC coefficients are removed for noise mitigation. (c) The removed striping noise. Units: K.\begin{align} &\begin{array}{rcl} \sigma_{\rm cross}^2(k,j)&=&\displaystyle\frac{1}{N}\sum_{i=1}^N((O-B)_{k,i,j}-\overline{(O-B)}_{k,i,j})^2 ,\\ \overline{(O-B)}_{k,i,j}&=&\displaystyle\frac{1}{N}\sum_{i=1}^N(O-B)_{k,i,j} , \ \ (7)\end{array} \end{align} where (O-B)k,i,j stands for the (O-B) difference at the ith FOV on the jth scan line within the kth data sample, N is the total number of FOVs, M is the number of scan lines within each of the datasets for the variance calculation, and K is the total number of data samples. In the calculation, N=90, M=200, and K is around 160. The smoothed brightness temperatures will be denoted as O smooth for SIs after noise mitigation.
Figure 6 shows the variations in along-track variances σ along2(k,i) and cross-track variances σ cross2(k,j) calculated using brightness temperatures before striping noise mitigation on 1 May 2014. The distribution of the along-track variance has line patterns for adjacent FOVs within some data samples due to cross-track correlations. By comparison, the distribution of the cross-track variance appears to be more random. The along-track variances generally have larger values than the cross-track variances, confirming that striping noise adds to along-track variances. The striping index calculated using Eq. (5) for Fig. 6 is 1.3513. Figure 7 shows variations in along-track variances σalong2(k,i) and cross-track variances σ cross2(k,j) after striping noise mitigation. The magnitudes of the along-track variances are significantly reduced while those of the cross-track variances change very little. The striping index for Fig. 7 is now reduced to 0.975.
Figure6. Variations in (a) along-track variances for channel 8 as a function of the sample group number and FOV (i) and (b) cross-track variances as a function of dataset number (k) and scan line (j) before striping noise mitigation on 1 May 2014. The total number of scan lines in each dataset is 200. The total number of datasets for both the ascending and descending nodes on 1 May is 162.
Figure7. As in Fig. 6 except for data with striping noise mitigated (PC3/IMF4). The mean value of the striping index at channel 8 is 0.975.
Figure8. Global distributions of channel 8 (a) O-B and (b) differences between smoothed brightness temperatures removed on 30 May 2014 on the ascending node. The first three IMFs of the first three PC coefficients are removed for noise mitigation. (c) The removed striping noise. Units: K.
Figure9. Variations in (a) along-track variances as a function of the sample group number and FOV (i) and (b) cross-track variances as a function of dataset number (k) and scan line (j) before striping noise mitigation on 30 May 2014. The total number of scan lines in each dataset is 100. The total number of datasets for both the ascending and descending nodes on 30 May is 164. (c) Variations in striping index as a function of dataset number (k). The dashed line shows the mean striping index (equal to 1.5146).
Figure10. As in Fig. 9 except for data with striping noise mitigated (3PC/3IMF). The mean value of the striping index is 1.013.Figure 11 shows the variations in SIs of MWTS-2 channel 8 with respect to date during two one-week periods. Along-track variances increased after the scan profile change while cross-track variances remained about the same, suggesting that the FY-3C MWTS-2 striping problem became even more severe after the scan profile change. The along-track variations after striping noise mitigation were noticeably reduced. The cross-track variations also decreased slightly due to the smoothing within the second and third PC coefficients. The SI index hovers around 1.0 after noise mitigation, indicating the effectiveness of the noise mitigation reported in this study.
Figure11. (a) Along-track variances, (b) cross-track variances, and (c) striping index at channel 8 during 1-7 May 2014 and 29 May to 4 June 2014 before (red) and after (blue) noise mitigation. Ascending and descending nodes are shown as open and solid markers, respectively.