删除或更新信息,请邮件至freekaoyan#163.com(#换成@)

Simultaneous voltammetric determination of guanine and adenine using MnO2 nanosheets and ionic liqui

本站小编 Free考研考试/2022-02-11

Simultaneous voltammetric determination of guanine and adenine using MnO2 nanosheets and ionic liquid-functionalized graphene combined with a permeation-selective polydopamine membrane
Zhang, S; Zhuang, XM; Chen, DD; Luan, F; He, T; Tian, CY; Chen, LX
发表期刊MICROCHIMICA ACTA
ISSN0026-3672
2019-07
卷号186期号:7页码:UNSP 450
关键词ElectrochemicalNanocompositesSensorGuanineAdenineFetal bovine serumMouse whole blood
研究领域Chemistry, Analytical
DOI10.1007/s00604-019-3577-4
产权排序[Zhang, Shuang; Zhuang, Xuming; Chen, Dandan; Luan, Feng; He, Tao; Tian, Chunyuan; Chen, Lingxin] Yantai Univ, Coll Chem & Chem Engn, Yantai 264005, Peoples R China; [Chen, Lingxin] Chinese Acad Sci, Yantai Inst Coastal Zone Res, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China
通讯作者Zhuang, Xuming(xmzhuang@iccas.ac.cn); He, Tao(13562512013@163.com); Chen, Lingxin(lxchen@yic.ac.cn)
作者部门海岸带环境工程技术研究与发展中心
英文摘要Guanine and adenine in blood samples can be detected by using an electrochemical sensor based on the use of manganese dioxide (MnO2) nanosheets and ionic liquid functionalized graphene (IL-GR) bound to a polydopamine (PDA) membrane. Both guanine and adenine undergo aredox reaction on the surface of the modified electrode. Cyclic voltammetry and differential pulse voltammetry were used to evaluate the electrochemical behavior of a glassy carbon electrode (GCE) modified with PDA/MnO2/IL-GR. The sensor allows for individual as well as simultaneous determination of guanine and adenine. The working voltage of differential pulse voltammetry at which data were acquired to establish the calibration plot: 0.6-1.2V for guanine, 0.8-1.4V for adenine, 0.4-1.4V for mixture of guanine and adenine. A wide detection range (10-300M), low detection limits (guanine: 0.25M; adenine: 0.15M), selectivity and reproducibility are demonstrated. The modified GCE was successfully applied to the analysis of guanine and adenine in spiked fetal bovine serum and mouse whole blood samples.
文章类型Article
资助机构National Natural Science Foundation of ChinaNational Natural Science Foundation of China [21778047, 21675138]; Department of Science and Technology of Shandong Province of China [2018GSF116011, GG201709290055]; Yantai City of China [2017ZH093]
收录类别SCI
语种英语
关键词[WOS]GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL SENSOR; NANOPARTICLES; COMPOSITE; OXIDE; NANOCOMPOSITE; FLUORESCENCE; PERFORMANCE; DOPAMINE
研究领域[WOS]Chemistry, Analytical
WOS记录号WOS:000471618500019
引用统计被引频次:35[WOS][WOS记录][WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cnhttp://ir.yic.ac.cn/handle/133337/24912
专题中科院海岸带环境过程与生态修复重点实验室_海岸带环境工程技术研究与发展中心
中科院海岸带环境过程与生态修复重点实验室

作者单位1.Yantai Univ, Coll Chem & Chem Engn, Yantai 264005, Peoples R China;
2.Chinese Acad Sci, Yantai Inst Coastal Zone Res, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China

推荐引用方式
GB/T 7714Zhang, S,Zhuang, XM,Chen, DD,et al. Simultaneous voltammetric determination of guanine and adenine using MnO2 nanosheets and ionic liquid-functionalized graphene combined with a permeation-selective polydopamine membrane[J]. MICROCHIMICA ACTA,2019,186(7):UNSP 450.
APAZhang, S.,Zhuang, XM.,Chen, DD.,Luan, F.,He, T.,...&Chen, LX.(2019).Simultaneous voltammetric determination of guanine and adenine using MnO2 nanosheets and ionic liquid-functionalized graphene combined with a permeation-selective polydopamine membrane.MICROCHIMICA ACTA,186(7),UNSP 450.
MLAZhang, S,et al."Simultaneous voltammetric determination of guanine and adenine using MnO2 nanosheets and ionic liquid-functionalized graphene combined with a permeation-selective polydopamine membrane".MICROCHIMICA ACTA 186.7(2019):UNSP 450.


PDF全文下载地址:

点我下载PDF
相关话题/海岸 环境工程 生态 过程 环境