删除或更新信息,请邮件至freekaoyan#163.com(#换成@)

Lung fluid and impedance cardiography (1998)_香港中文大学麻醉及深切治療學系 (ANS)

香港中文大学 辅仁网/2017-06-20

Lung fluid and impedance cardiography
Publication in refereed journal


香港中文大学研究人员 ( 现职)
郭志德教授 (麻醉及深切治疗学系)


全文


引用次数
Web of Sciencehttp://aims.cuhk.edu.hk/converis/portal/Publication/9WOS source URL

其它资讯

摘要Serial thermodilution and impedance cardiac output measurements in two critically ill patients are presented. Impedance cardiography failed to detect changes in cardiac output and provided values lower than those derived from thermodilution. Chest X-ray examination and changes in thoracic impedance suggested that these two patients had significantly increased extravascular lung water. This failure of impedance cardiography is attributed to aberrant electrical conduction though the lungs as a result of increased lung fluid that alters the impedance waveform. Although reliable when used in normal subjects, impedance cardiography appears not to provide accurate measurements in critically ill patients.

着者Critchley LAH, Critchley JAJH
期刊名称Anaesthesia
出版年份1http://aims.cuhk.edu.hk/converis/portal/Publication/9http://aims.cuhk.edu.hk/converis/portal/Publication/98
月份4
日期1
卷号53
期次4
出版社BLACKWELL SCIENCE LTD
页次36http://aims.cuhk.edu.hk/converis/portal/Publication/9 - 372
国际标準期刊号0003-240http://aims.cuhk.edu.hk/converis/portal/Publication/9
电子国际标準期刊号1365-2044
语言英式英语

关键词complications, pulmonary oedema; measurement technique, impedance cardiography, thermodilution; monitoring, cardiac output
Web of Science 学科类别Anesthesiology; ANESTHESIOLOGY

相关话题/国际 英语 电子 语言 学科