Comparative Studies on Calculation Methods of Shear Behavior of Reinforced Concrete Beams of Chinese Modern Reinforced Concrete Buildings
Qing Chun1,2, Koenraad Van Balen3,Yidan Han1
(1.School of Architecture,Southeast University, Nanjing 210096, China; 2. Key Lab of Urban & Architectural Heritage Conservation, Ministry of Education, Southeast University, Nanjing 210096, China; 3. Department of Civil Engineering, KU.Leuven, Heverlee 3001, Belgium)
Abstract:
In order to study the calculation methods of shear behavior of reinforced concrete beams of Chinese modern reinforced concrete buildings, this paper carried out tests on the concrete compressive strength of 12 Chinese modern concrete buildings, the mechanical properties of 66 rebars from different Chinese modern concrete buildings, and the concrete cover thickness of 9 Chinese modern concrete buildings, and the actual material properties and structural configurations have been obtained. Then, the comparison on calculation methods include the Chinese original calculation method, the Chinese present calculation method, the American present calculation method and the European present calculation method is studied with case analysis method. The results show that the Chinese original calculation method of shear behavior of reinforced concrete beams is based on the allowable stress calculation method, and the design safety factors are 3.55-4.00. The standard value of the compressive strength of concrete cubes is 8.48 MPa, the standard value of the concrete tensile strength is 1.20 MPa, the standard value of the yield strength of rectangular rebars is 229.56 MPa, and the standard value of the yield strength of round rebars is 276.82 MPa. The average value of the concrete cover thickness of beams and columns is 35.96 mm. In term of calculation area of hoop rebars of reinforced concrete beams, without considering earthquake loads, the Chinese original structural calculation method is safer than the Chinese present structural calculation method, but is more unsafe than the American present structural calculation method and the European present structural calculation method. The results can provide the support for structural safety assessments and repair designs of Chinese modern reinforced concrete buildings.
Key words: reinforced concrete buildings the Republic of China era from 1912 to 1949 shear behavior calculation method comparative study
DOI:10.11916/j.issn.1005-9113.2016.02.001
Clc Number:TU375.1
Fund:
Chun Qing, Van Balen Koenraad, Han Yidan. Comparative Studies on Calculation Methods of Shear Behavior of Reinforced Concrete Beams of Chinese Modern Reinforced Concrete Buildings[J]. Journal of Harbin Institute of Technology, 2016, 23(2): 1-8. DOI: 10.11916/j.issn.1005-9113.2016.02.001.
Fund Sponsored by the National Natural Science Foundation of China (Grant No.51138002) and a Foundation for the Author of National Excellent Doctoral Dissertation of PR China (Grant No.201452) Corresponding author E-mail: cqnj1979@163.com Article history Received: Mar 30, 2015
Contents Abstract Full text Figures/Tables PDF
Comparative Studies on Calculation Methods of Shear Behavior of Reinforced Concrete Beams of Chinese Modern Reinforced Concrete Buildings
Chun Qing1,2, Van Balen Koenraad3, Han Yidan1
1. School of Architecture, Southeast University, Nanjing 210096, China;
2. Key Lab of Urban & Architectural Heritage Conservation, Ministry of Education, Southeast University, Nanjing 210096, China;
3. Department of Civil Engineering, KU.Leuven, Heverlee 3001, Belgium
Received: Mar 30, 2015
fund: Sponsored by the National Natural Science Foundation of China (Grant No.51138002) and a Foundation for the Author of National Excellent Doctoral Dissertation of PR China (Grant No.201452)
Corresponding author: E-mail: cqnj1979@163.com
Abstract: In order to study the calculation methods of shear behavior of reinforced concrete beams of Chinese modern reinforced concrete buildings, this paper carried out tests on the concrete compressive strength of 12 Chinese modern concrete buildings, the mechanical properties of 66 rebars from different Chinese modern concrete buildings, and the concrete cover thickness of 9 Chinese modern concrete buildings, and the actual material properties and structural configurations have been obtained. Then, the comparison on calculation methods include the Chinese original calculation method, the Chinese present calculation method, the American present calculation method and the European present calculation method is studied with case analysis method. The results show that the Chinese original calculation method of shear behavior of reinforced concrete beams is based on the allowable stress calculation method, and the design safety factors are 3.55-4.00. The standard value of the compressive strength of concrete cubes is 8.48 MPa, the standard value of the concrete tensile strength is 1.20 MPa, the standard value of the yield strength of rectangular rebars is 229.56 MPa, and the standard value of the yield strength of round rebars is 276.82 MPa. The average value of the concrete cover thickness of beams and columns is 35.96 mm. In term of calculation area of hoop rebars of reinforced concrete beams, without considering earthquake loads, the Chinese original structural calculation method is safer than the Chinese present structural calculation method, but is more unsafe than the American present structural calculation method and the European present structural calculation method. The results can provide the support for structural safety assessments and repair designs of Chinese modern reinforced concrete buildings.
Key words: reinforced concrete buildings the Republic of China era from 1912 to 1949 shear behavior calculation method comparative study
1 IntroductionIn China, reinforced concrete structures were first built in the Republic of China era from 1912 to 1949. In the numerous buildings built in this era, reinforced concrete buildings account for a large proportion. Nowadays, in the Chinese national cultural heritage conservation units, especially in the provincial and municipal cultural heritage conservation units, reinforced concrete buildings of the Republic of China era represent a considerable number of heritages. For example, according to Ref. [1], the existing reinforced concrete buildings of the Republic of China era account for 64.2% of the total existing buildings of this era in Nanjing. Reinforced concrete buildings in the Republic of China era are developed in a special historical period transferring from the ancient architectural structures to the contemporary architectural structures. Chinese modern concrete buildings are very different from present concrete buildings in many ways, such as material properties, structural calculation methods and structural configurations. For example, the longitudinal rebars of Chinese modern concrete buildings are commonly rectangular ribbed rebars which are very different from the present round deformed rebars (as shown in Fig. 1).
Figure 1
Figure 1 Rectangular rebars in Chinese modern concrete members
The structural calculation method of reinforced concrete structure evolves through several stages. The first stage is the allowable stress calculation method, and then it is the plastic state calculation method, and then it is the limit state calculation method, and last it is the probabilistic limit state calculation method[2].
In China, there are very few research reports about the structural calculation method of Chinese modern reinforced concrete buildings. Zhao[3] referenced the American code for concrete structure, and presented the structural calculation methods of members of Chinese modern concrete structures. Zhang[4]studied the structural calculation methods of Chinese modern concrete structures and presented the calculation methods and the configurations of concrete beams, concrete columns, concrete slabs, and concrete foundations. Chen[5]studied the calculation methods of internal forces of Chinese modern concrete structures, and introduced the structural calculation methods of concrete beams, concrete columns, concrete slabs, and concrete foundations based on a case study. Wang[6] introduced the structural calculation methods of Chinese modern concrete structure based on the case studies. Chen[7] introduced the regulations of British concrete structural design. Wang[8] made a brief introduction of the structural regulations of Shanghai International Settlement of the Republic of China era. The reports above were all published in the Republic of China era, and only introduced the original structural calculation methods of Chinese modern concrete buildings. Lin et al.[9] carried out an experiment of the rebars taken from a modern concrete building in Shanghai, and presented the relevant yield strength and limited tensile strength. Wang[10] studied the repair methods of a modern concrete building in Xiamen, and presented the adaptive test methods of concrete strength, durability problem, and rebar quality. Shi[11] studied the conservation methods of the modern concrete buildings in Wuhan, and preliminary put forward the adaptive strengthening and repair methods for these buildings. Chen et al.[12] carried out the test and assessment of a modern concrete building built in 1930s, and then presented the relevant strengthening and repair methods.
In Europe, North America and New Zealand, a lot of research on conservation methods of historic concrete buildings has been carried out. Peter et al.[13] researched the history, the material properties, the defect causes, and the conservation strategies of historic concrete structures in New Zealand. Denis[14]studied the concrete characteristics and the repair principles of the historic concrete in Scotland. Gebregziabhier[15] researched the durability problems, the repair principles, and the repair methods of the 20th century reinforced concrete heritage structures. Gonalves[16] studied the corrosion of concrete reinforcement and the survey techniques used to detect corrosion in historic concrete structure. Luca et al.[17]carried out the research on the electrochemical realkalisation technique used to stop rebar corrosion in carbonated concrete. Dimitri[18] studied the reliability of a multi-storey historic concrete building based on the FEM analysis, considering the uncertainty of the material performance, the geometry shape, the load and the structural model. Coney[19] studied the method and process of repair and conservation of historic concrete structure. Ince et al.[20] introduced the repair methods of a historic concrete building in Moscow. Searls et al.[21]studied the repair methods of the city hall of Atlanta built in 1930. Qazi[22] researched the structural performance of a historic concrete building under earthquake loads.
So far, the present research mainly focuses on conservation techniques of historic concrete buildings, and the comparative study on structural calculation methods of reinforced concrete members of Chinese modern reinforced concrete buildings is still in an early stage. In this paper, the comparative studies on the original calculation method and the present calculation methods of shear behavior of reinforced concrete beams of Chinese modern reinforced concrete buildings are carried out with the consideration of the actual material properties and structural configurations.
2 Material Properties and Structural ConfigurationsAccording to Refs.[3-8], the structural calculation method of Chinese modern reinforced concrete buildings is the allowable stress calculation method based on elastic theory.
2.1 Allowable Stress and Safety FactorAccording to Refs.[3-5], the limited strength, the allowable stress, and the safety factors of concrete and rebar of the Republic of China era are shown in Table 1.
表 1
Table 1 Allowable stress of concrete and rebar of the Republic of China era MaterialLoadLimited strength(MPa)Allowable stress(MPa)Safety factor
Compression16.564.144.0
ConcreteTension1.660.414.0
Shearing- 0.41-
Compression248.3662.094.0
RebarTension441.54110.38-124.184.0-3.55
Shearing- 82.79-
Note: For Chinese modern concrete buildings, elastic modulus of rebar is 15 times that of concrete.
Table 1 Allowable stress of concrete and rebar of the Republic of China era
The results in Table 1 show that the structural safety factors of the Chinese original structural calculation method are in a range of 3.55 to 4.00, namely, the structural safety reservation of the Chinese original structural calculation method is relatively large.
2.2 Actual Material PropertiesAccording to Refs.[3-5], the concrete mixture of the Republic of China era is often made in a ratio of 1(cement): 2(sand): 4(gravel) by volume. The compressive strength can reach 8.28 MPa after the maintenance of a week, 13.78 MPa after the maintenance of four weeks, 20.69 MPa after the maintenance of four months, and 24.13 MPa after the maintenance of twelve months, respectively. The appropriate diameter of the gravel in the concrete is required to be from 12.7 mm to 25.4 mm, and the appropriate diameter of the sand in the concrete is required to be about 1.27 mm. According to the conversion analysis, the strength grade of concrete of the Republic of China era is comparable to the present strength grade of C15 concrete. For the original structural calculation method of the Republic of China era, the limited compressive strength of concrete is 16.56 MPa, and the allowable stress of concrete is 4.14 MPa. Through the on-site tests of 12 Chinese typical modern concrete buildings, 154 data of concrete compressive strength have been collected and analyzed, as shown in Table 2. The results show that the compressive strength of concrete of the Republic era is between 10 MPa and 20 MPa, and the results coincide with the requirement of the Chinese original structural calculation method. Through the statistical analysis of these data, the test results of compressive strength of concrete cubes overall follow the rule of normal distribution, and the average of the compressive strength of concrete cubes is 16.36 MPa, as shown in Fig. 2.
表 2
Table 2 Test results of the compressive strength of concrete cubes Typical caseCompressive strength of concrete cubes
Average (MPa)Cov (%)
Main hall of Tomb of Yu in Shaoxing (1933)17.1816.28
Former site of Post Office in Sun Yat-sen′s Mausoleum (1947)16.0815.79
No.1 building of Zhongshan East Road in Nanjing (1935)12.052.58
Former site of Heji Foreign Firm (1916)12.5317.53
Dahua Cinema in Nanjing (1934)17.6214.20
Former site of Capital Cinema in Nanjing (1931)13.4414.28
Dacheng Factory in Changzhou (1935)21.3117.80
Yijiang City Gate in Nanjing (1946)12.287.57
Main hall of Nanjing Museum (1937)20.609.69
Former site of Jiangsu Post Office (1918)15.4016.69
Huangpu hall of Jiangsu Conference Center (1931)16.2014.49
Former site of Nanjing Merchants Bureau (1947)14.3019.73
Note: Cov is the coefficient of variation of the test values.
Table 2 Test results of the compressive strength of concrete cubes
Figure 2
Figure 2 Frequency histogram and normal distribution of compressive strength of modern concrete cubes
According to Refs.[3-5], the limited tensile strength of rebar of the Republic of China era is required to be more than 441.54 MPa, and the allowable stress of rebar of the Republic of China era is required to be more than 110.38 MPa. The physical and mechanical performance of 66 rebars including 36 rectangular rebars and 30 round rebars taken from different cities and different buildings are tested and analyzed. The results show that the yield strength of the rectangular rebars overall follow the rule of normal distribution, and the average of them is 278.60 MPa. The yield strength of the round rebars also overall follow the rule of normal distribution, and the average of them is 350.65 MPa.
According to the requirements of the Chinese present design code for concrete structure[23-24], standard values of material strength need to ensure 95% guarantee rate, and test results of material strength shall follow the rule of normal distribution. fk=fm-1.645×σ, where fk is standard value of material strength; fm is average value of material strength; σ is standard deviation of material strength. f=fk/γ, where f is design value of material strength, and γ is partial factor.
According to the actual test results, for the Chinese present structuralcalculation method, the standard value of compressive strength of concrete cubes of the Republic of China era is obtained as follows: fcuk=fcum-1.645σcu=16.36-1.645×4.79=8.48 MPa. The relevant standard value of axial compressive strength of concrete is obtained as follows: fck=0.67fcuk=0.67×8.48=5.68 MPa. The relevant standard value of tensile strength of concrete is obtained as follows: ftk=0.88×0.395fcuk0.55(1-1.645δfcu)0.45=1.20 MPa. The standard value of yield strength of rectangular rebar of the Republic of China era is achieved as follows: fyk=fym-1.645σy=278.60-1.645×29.81=229.56 MPa. The standard value of yield strength of round rebar of the Republic of China era is achieved as follows: fyk=fym-1.645σy=350.65-1.645×44.88=276.82 MPa. The relevant design value of axial compressive strength of concrete is obtained as follows: fc=fck/γc=5.68/1.35=4.21 MPa. The relevant design value of tensile strength of concrete is obtained as follows: ft=ftk/γc=1.20/1.35=0.89 MPa. The design value of yield strength of rectangular rebar of the Republic of China era is obtained as follows: fy=fyk/γy=229.56/1.1=208.69 MPa. The design value of yield strength of round rebar of the Republic of China era is obtained as follows: fyv=fyk/γy=276.82/1.1=251.65 MPa.
According to Refs.[23-26], for the American present structural calculation method, according to the conversion analysis, the compressive strength of concrete cylinders of the Republic of China era is obtained as follows: fc′= fcuk×0.846/1.003=7.15 MPa. The relevant tensile strength of concrete is obtained as follows: ft′=0.333fc′=0.89 MPa. In the American code of ACI 318, there is no difference between standard value and design value, so the yield strength of rectangular rebar of the Republic of China era is obtained as follows: fyk=229.56 MPa. The yield strength of round rebar of the Republic of China era is obtained as follows: fyk=276.82 MPa. For the European present structural calculation method, the characteristic value of compressive strength of concrete of the Republic of China era is obtained as follows: fck=fcuk/1.226=6.92 MPa. The relevant characteristic value of tensile strength of concrete is obtained as follows: ftk=0.7×0.3×fck2/3=0.76 MPa. The design value of compressive strength of concrete of the Republic of China era is obtained as follows: fc= fck/γc =6.92/1.5=4.61 MPa. The relevant design value of tensile strength of concrete is obtained as follows: ft=ftk/γc=0.76/1.5=0.51 MPa. The design value of yield strength of rectangular rebar of the Republic of China era is obtained as follows: fy=fyk/γy=229.56/1.15=199.62 MPa. The design value of yield strength of round rebar of the Republic of China era is obtained as follows: fyv=fyk/γy=276.82/1.15=240.71 MPa.
The concrete cover thickness of Chinese original structural calculation method is required to be more than 38.1 mm for beams or columns. 139 test data of concrete cover thickness of beams and columns have been collected from 9 typical Chinese modern concrete buildings. According to the analysis of these data, the average of the concrete cover thickness of beams or columns is 35.96 mm. The results are shown in Table 3. The test results of concrete cover thickness of beams and columns approximately follow the rule of normal distribution, as shown in Fig. 3, but the discreteness of these test data is relatively large because of restriction of construction techniques and damages in the wars at that time.
表 3
Table 3 Test results of concrete cover thickness of some typical cases Typical caseConcrete cover thickness of beams and columns
Average (MPa)Cov (%)
Main hall of Tomb of Yu in Shaoxing (1993)40.619.0
No. 1 building of Zhongshan East Road in Nanjing (1935)32.120.8
Dahua Cinema in Nanjing (1934)34.218.8
Dacheng Factory in Changzhou (1935)36.011.8
Main hall of Nanjing Museum (1937)34.819.5
Huangpu hall of Jiangsu Conference Center (1931)34.111.0
Former site of Heji Foreign Firm (1916)35.821.6
Former site of Jiangsu Post Office (1918)41.617.3
Former site of Nanjing Merchants Bureau (1947)36.617.7
Table 3 Test results of concrete cover thickness of some typical cases
Figure 3
Figure 3 Frequency histogram and normal distribution of concrete cover thickness of modern concrete columns and beams
3 Comparative Analysis on the Original Calculation Method and the Present Calculation Methods of Shear Behavior of Reinforced Concrete BeamsAccording to Refs.[3-5], the calculation diagram of shear capacity of concrete reinforced beam of the Chinese original structural design method is shown in Fig. 4.
Figure 4
Figure 4 Calculation diagram of shear capacity of reinforced concrete beam
According to the Chinese original structural calculation method, shear force of concrete reinforced beam is born by concrete and hoop rebar.Concrete part only contributes shear bearing capacity calculated by the allowable stress of concrete, and hoop rebars contribute the other shear bearing capacity. The calculation formulas of diameter, shape, and distance of hoop rebars of concrete reinforced beam are as follows:
${v}'=\frac{V}{bjd}$ (1)
${{x}_{c}}=6\left( \frac{\left[ {v}'-{{v}_{1}} \right]l}{{{v}'}} \right)$ (2)
${{V}_{2}}=\frac{\left( {v}'-{{v}_{1}} \right)b{{x}_{c}}}{2}$ (3)
${{N}_{V}}=\frac{{{V}_{2}}}{{{f}_{V}}{{A}_{V}}{{^{\prime }}^{\prime }}}$ (4)
$S=\frac{{{f}_{V}}{{A}_{V}}{{^{\prime }}^{\prime }}}{\left( {v}'-{{v}_{1}} \right)b}$ (5)
where V is the maximum shear force of beam; v′ is the maximum shear stress of beam; j is the ratio of the arm of force to the distance between center of tensile rebar and compressive side of beam; b is the width of beam; d is the distance between center of tensile rebar and compressive side of beam; v1 is the allowable shear stress of concrete, and it is 0.41 MPa; xc is the distance between the support and the location of zero shear force; l is the span of beam; V2 is the total shear bearing capacity of all hoop rebars; Nv is the quantity of hoop rebars; fv is the allowable shear stress of hoop rebars; Av″ is equal to the area of single leg of hoop rebar multiply the number of legs of hoop rebar; S is the minimum distance of hoop rebars close to support.
Comparing with the present calculation methods including the Chinese present calculation method, the American present calculation method and the European present calculation method, the Chinese original calculation method is founded based on the theory of elastic material mechanics, shear force is undertaken by concrete part and hoop rebar part together. The design strength of hoop rebar is its allowable stress. The Chinese present calculation method is founded based on the theory of semi empirical and semi theoretical model, shear force is undertaken by concrete part and hoop rebar part together. The design strength of hoop rebar is its yield strength. The American present calculation method is founded based on the theory of modified truss model, shear force is undertaken by concrete part and hoop rebar part together. The design strength of hoop reinforcement is its yield strength. The European present calculation method is founded on the theory of truss model, shear force is undertaken by hoop rebar part when hoop rebar is yielding or concrete part when concrete is crushed. The design strength of hoop rebar is its yield strength. The calculation models of these four methods are very different.
In this paper, taking examples of the simply supported beams, the comparative studies on calculation methods of shear behavior of reinforced concrete beams of Chinese modern reinforced concrete buildings are carried out. The calculation methods include the Chinese original calculation method, the Chinese present calculation method, the American present calculation method and the European present calculation method.
Some typical rectangular beams bearing distributed loads are taken as the examples for calculation, considering different cross section dimension from 250 mm×500 mm (width×height) to 450 mm×900 mm (width×height), different span, and different live loads. For the Chinese original structural calculation method (M1), the design strength of concrete and rebar are the relevant allowable stress. The allowable stresses of concrete and rebar are obtained according to Table 1. For the Chinese present structural calculation method (M2), the design compressive strength of concrete is: fc=4.21 MPa, the design tensile strength of concrete is: ft=0.89 MPa, the design shear strength of rebar is: fyv=251.65 MPa. For the American present structural calculation method (M3), the design compressive strength of concrete is: fc=7.15 MPa, the design tensile strength of concrete is: ft=0.89 MPa, the design shear strength of rebar is: fyy=276.82 MPa. For the European present calculation design method (M4), the design strength of concrete is: fc=4.61 MPa, the design tensile strength of concrete is: ft=0.51 MPa, the design shear strength of rebar is: fyy=240.71 MPa. The comparison of calculation results with different methods are shown in Tables 4 and 5.
表 4
Table 4 Comparison on maximum design shear force of reinforced concrete beams Dimension of beam(mm×mm)Span of beam(m)Live load(kN/m)Maximum design shear force (kN)
M1M2Error(%)M3Error(%)M4Error(%)
200×4003.02033.0045.60-3851.60-5649.05-49
200×4503.52038.9453.73-3860.73-5657.82-48
250×5003.53057.9780.06-3890.56-5686.13-49
250×5504.03066.8892.25-38104.25-5699.28-48
250×6004.53075.94104.63-38118.13-56112.64-48
300×6504.53589.72123.41-38139.16-55132.93-48
300×7005.035100.63138.25-37155.75-55148.97-48
300×7505.535111.72153.31-37172.56-54165.26-48
400×8006.040144.00196.80-37220.80-53212.40-48
400×8506.540157.63215.15-36241.15-53232.29-47
400×9007.040171.50233.80-36261.80-53252.53-47
Note: Error of maximum design shear force=(M1-M2 or M3 or M4) / M1.
Table 4 Comparison on maximum design shear force of reinforced concrete beams
表 5
Table 5 Comparison on area of hoop rebars of reinforced concrete beams Dimension of beam(mm×mm)Span of beam(m)Live load(kN/m)Area of hoop rebars (mm2/mm)
M1M2Error(%)M3Error(%)M4Error(%)
200×4003.0200.260.002990.362-390.311-20
200×4503.5200.310.016950.386-250.322-4
250×5003.5300.480.053890.539-120.42811
250×5504.0300.560.075860.576-30.44620
250×6004.5300.620.095850.60820.46126
300×6504.5350.530.045910.611-150.5006
300×7005.0350.600.068890.649-80.51814
300×7505.5350.670.088870.683-20.53420
400×8006.0400.610.027960.751-230.642-5
400×850 6.5400.680.048930.785-150.6593
400×9007.0400.500.068860.818-640.675-35
Note: Error of area of hoop rebars=(M1-M2 or M3 or M4)/M1.
Table 5 Comparison on area of hoop rebars of reinforced concrete beams
The results in Tables 4 and 5 show that the maximum design shear forces of the Chinese original structural calculation method are 36%-38%, 53%-56% and 47%-49% less than those of the Chinese, the American and the European present structural calculation methods respectively. The calculation area of the hoop rebars of the Chinese original structural calculation method are 85%-99% lager than those of the Chinese present structural design method, and are 0%-64% and 0%-35% less than those of the American and the European present structural calculation methods respectively. So, in term of maximum shear capacity of reinforced concrete beam, without considering earthquake loads, the shear capacity of the Chinese original structural calculation method is smaller than that of the Chinese present structural calculation method, but is larger than that of the American present structural calculation method and that of the European present structural calculation method. In other words, according to the requirements of the Chinese present structural calculation method, the shear bearing capacity of concrete beams of the Republic of China era are basically safe. But according to the requirements of the American present structural calculation method and the European present structural calculation method, the shear bearing capacity of concrete beams of The Republic of China era are not safe.
4 Conclusions1) he original structural calculation method of reinforced concrete structure of the Republic of China era is based on the allowable stress design method. The design safety factors are 3.55-4.00.
2) ccording to the statistic analysis of the test results of compressive strength of concrete cubes, the test data follow the rule of normal distribution, and the average compressive strength of concrete cubes of the Republic of China era is 16.36 MPa, and the standard value of compressive strength of concrete cubes of the Republic of China era is 8.48 MPa. The test results coincide with the requirements of the Chinese original structural calculation method.
3) ccording to the statistical analysis of the test results of strength of rebars, the test data of rectangular rebars and round rebars overall follow the rule of normal distribution, and the standard value of the yield strength of rectangular rebars is 229.56 MPa, and the standard value of the yield strength of round rebars is 276.82 MPa.
4) ccording to the statistical analysis of the test results of concrete cover thickness, the test results of concrete cover thickness of beams and columns approximately follow the rule of normal distribution. The average of the concrete cover thickness of beams and columns is 35.96 mm. The actual concrete cover thickness of columns and beams are appreciably less than the requirement of the Chinese original structural calculation method. The discreteness of these test data is relatively large because of the restriction of construction techniques at that time.
5) Based on the comparative analysis of the different structural calculation methods, in term of calculation area of hoop rebars of reinforced concrete beam, without considering earthquake loads, the Chinese original structural calculation method is safer than the Chinese present structural calculation method, but is more unsafe than the American present structural calculation method and the European present structural calculation method.
6) he original structural calculation method of reinforced concrete structures of the Republic of China era doesn’t consider earthquake loads, while many of these buildings are located in earthquake prone area. These buildings lack aseismic structural configurations, and will be dangerous when an earthquake happens. The structural assessment method and the structural safety level of reinforced concrete structures of the Republic of China era with considering earthquake loads will be further studied in future.
References
[1]Liu X J. Overview of Chinese Modern Architecture: The Part of Nanjing Articles.Beijing: China Building Industry Press, 1992.(0)
[2]Gu X L. Basic Principles of Concrete Structures.Shanghai: Tongji University Press, 2004.(0)
[3] Zhao F L. Reinforced Concrete Structure. Shanghai: Chinese Engineers Association, 1935. (0)
[4] Zhang J S. Simplified Reinforced Concrete Structure. Shanghai: World Book Store, 1948. (0)
[5] Chen Z K. Practical Plan Guides for Reinforced Concrete Structure. Shanghai: Chenkui Architecture Office, 1936. (0)
[6]Wang J. Design for reinforced concrete structure.Journal of Chinese Architecture,1934, 2(1): 65-67.(0)
[7]Chen H D. Review of reinforced concrete structure in London, UK.Journal of Chinese Architecture,1935, 3(1): 38-41.(0)
[8]Wang J. Architectural regulations of shanghai international settlement.Journal of Chinese Architecture,1934, 2(1): 65-67.(0)
[9]Lin F, Gu X L, Xiao B H. Strength inspection for steel rebars in historical buildings using hardness method.Structural Engineers,2010, 26(1): 108-112.(0)
[10] Wang W Y. Research on Reinforcement and Appraisement of Historic Buildings. Shanghai: Tongji University, 2004. (0)
[11] Shi C F. Study of the Damage Detection and Remedial Technology for Wuhan Historical Buildings. Wuhan: Huazhong University of Science & Technology, 2005. (0)
[12]Chen D C, Hu H B. Detection and reinforcement design of a modern architecture.Industrial Construction,2007, 37(7): 100-103.(0)
[13] Peter R, Kate S, Jeremy S. Historic Concrete Structures in New Zealand-Overview, Maintenance and Management. Wellington: Science & Technical Publishing, 2008. (0)
[14] Denis U. Historic Concrete in Scotland Part 1: History and Development. Edinburgh: Historic Scotland, 2013. (0)
[15] Gebregziabhier T. Durability Problems of 20th Century Reinforced Concrete Heritage Structures and Their Restorations. Barcelona: Barcelona Technical University of Catalonia, 2008. (0)
[16] Gon?alves A P. Corrosion Prevention in Historic Concrete-Monitoring the Richards Medical Laboratories. Philadelphia: University of Pennsylvania, 2011. (0)
[17]Luca B, Maddalena C, Elena R. Conservation of historical reinforced concrete structures damaged by carbonation induced corrosion by means of electrochemical realkalisation.Journal of Cultural Heritage,2008, 9(4): 376-385.(0)
[18]Dimitri V V. Reliability assessment of damaged RC framed structures.Journal of Structural Engineering,1997, 123(7): 889-895.(0)
[19]Coney W B. Restoring historic concrete.Constr Specifier,1989, 42: 42-51.(0)
[20]Ince S, Yigin H. Reconstruction and restoration of Petrovski passage.ASTM Special Technical Publication,1996, 125(8): 285-293.(0)
[21]Searls C L, Thomasen S E. Repair of the terra-cotta faade of Atlanta City.Structural Repair and Maintenance of Historical Buildings,1991, 45(3): 247-257.(0)
[22]Qazi S A. Earthquake strengthening of a twelve story non-ductile concrete frame building with unreinforced masonry using displacement control criterion.Structural Engineering in Natural Hazards Mitigation,1993, 13(3): 331-336.(0)
[23]Gong J X, Wei W W, Hu J S. Comparison on the Chinese Codes, the American Codes and the European Codes for Design of Concrete Structures.Beijing: China Building Industry Press.2007.(0)
[24]China Academy of Building Research. Code for Design of Concrete Structures: GB50010-2010.Beijing: China Architecture & Building Press, 2011.(0)
[25] American Concrete Institute. Building Code Requirements for Structural Concrete: ACI-318-05. Farmington Hills, USA: American Concrete Institute, 2005. (0)
[26] European Committee for Standardization. 2004 Eurocode 2: Design of Concrete Structures-Part 1-1: General Rules and Rules for Buildings: EN 1992-1-1. Brussels, Belgium: CEN, 2004. (0)
删除或更新信息,请邮件至freekaoyan#163.com(#换成@)
Comparative Studies on Calculation Methods of Shear Behavior of Reinforced Concrete Beams of Chinese
本站小编 哈尔滨工业大学/2019-10-23
相关话题/Comparative Studies Calculation Methods Shear
Review: Energy Methods for Multiaxial Fatigue Life Prediction
Review: Energy Methods for Multiaxial Fatigue Life Prediction Author NameAffiliationZheng ZhongSchool of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, Guangdong,ChinaYingya LuUnited Automotive Electronic Systems Co., Ltd., Shanghai 201206, China ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2020-12-05Shearlet变换与核各向异性扩散的图像噪声抑制
Shearlet变换与核各向异性扩散的图像噪声抑制吴一全1,2,3,叶志龙1,万红1,刚铁2(1.南京航空航天大学电子信息工程学院,210016南京;2.先进焊接与连接国家重点实验室(哈尔滨工业大学),150001哈尔滨;3.深圳市城市轨道交通重点实验室(深圳大学),518060深圳)摘要:为了更有 ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Calculation of Circumferential Modal Frequencies of Permanent Magnet Synchronous Motor
Calculation of Circumferential Modal Frequencies of Permanent Magnet Synchronous Motor Shenbo Yu, Shuangshuang Zhong, Haining Zhao, Pengpeng Xia,Kai Guo (School of Mechanical Engineering, Shenyang University of Technology, Sheny ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Calculation of Solidification Process of Continuous Cast Bar
Calculation of Solidification Process of Continuous Cast Bar A I Golodnov, R K Mysik, A V Sulitsin, S V Brusnitsyn, I A Gruzdeva (Ural Federal University, Russia, Ekaterinburg) Abstract: ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Two Hybrid Methods Based on Rough Set Theory for Network Intrusion Detection
Two Hybrid Methods Based on Rough Set Theory for Network Intrusion Detection Na Jiao (Dept. of Information Science and Technology, East China University of Political Science and Law, Shanghai 201620, China) ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Research on Comparison and Evaluation Studies of Several Smoothing Denoising Method Based on γ-ray S
Research on Comparison and Evaluation Studies of Several Smoothing Denoising Method Based on γ-ray Spectrum Detector Jian-Feng He1,2, Fang Fang1, Yao-Zong Yang1, Yue-Shun He2, Bin Tang2 (1. College of Nuclear Technology and Aut ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Inversion Methods of Optical Constants of Semitransparent Solid Materials from Transmittance Spectro
Inversion Methods of Optical Constants of Semitransparent Solid Materials from Transmittance Spectrograms Dong Li 1,2, Xin-Lin Xia 1, Qing Ai 1 (1.School of Energy Science and Engineering, Harbin Institute of Technology, Harbin ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Quasi Dynamic Calculation of Local Stiffness of Angular Contact Ball Bearings
Quasi Dynamic Calculation of Local Stiffness of Angular Contact Ball Bearings Zhen-Huan Ye1, Chuan-Wei Zhang1, Le Gu 1,2, Li-Qin Wang1, De-Zhi Zheng1 (1. School of Mechatronics Engineering, Harbin Institute of Technology, Harbi ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Comparative Study on the Infrared Radiance Field of Building Surface under Sunshine Conditions and R
Comparative Study on the Infrared Radiance Field of Building Surface under Sunshine Conditions and Rainfall Conditions Ming Xie1, Hai-Qiang Wang2, Xiao-Chen Xie3, Xiao-Chun Wang1, He-Ping Tan1 (1. School of Energy Science and En ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24Model Reduction Methods for High-Rise Buildings with Active Mass Damper Control Systems
Model Reduction Methods for High-Rise Buildings with Active Mass Damper Control Systems Jun Teng, Hou-Bing Xing, Cheng-Yin Liu (Shenzhen Key Lab of Urban & Civil Engineering Disaster Prevention & Reduction, Harbin Institute of T ...哈尔滨工业大学科研学术 本站小编 哈尔滨工业大学 2019-10-24