Model Reduction Methods for High-Rise Buildings with Active Mass Damper Control Systems

本站小编 哈尔滨工业大学/2019-10-24

Model Reduction Methods for High-Rise Buildings with Active Mass Damper Control Systems

Jun Teng, Hou-Bing Xing, Cheng-Yin Liu

(Shenzhen Key Lab of Urban & Civil Engineering Disaster Prevention & Reduction, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen 518055, China)



Abstract:

To improve the performance of an active mass damper control system, the controller should be designed based on a reduced-order model. An improved method based on balanced truncation method was proposed to reduce the dimension of high-rise buildings, and was compared with other widely used reduction methods by using a framework with ten floors. This optimized method has improvement of reduction process and choice of the order. Based on the reduced-order model obtained by the improved method and pole-assignment algorithm, a controller was designed. Finally, a comparative analysis of structural responses, transfer functions, and poles was conducted on an actual high-rise building. The results show the effectiveness of the improved method.

Key words:  high-rise building  active mass damper  model reduction  controller design

DOI:10.11916/j.issn.1005-9113.2013.06.006

Clc Number:TU352

Fund:


相关话题/Model Reduction Methods High-Rise Buildings Active Mass Damper