English Abstract
Research and analysis on lidar performance with intrinsic fluorescence biological aerosol measurements
Rao Zhi-Min,Hua Deng-Xin,
He Ting-Yao,
Le Jing
1.School of Mechanical and Precision Instrument Engineering, Xi'an University of Technology, Xi'an 710048, China
Fund Project:Project supported by the National Natural Science Foundation of China (Grant Nos. 61275185, 41405028) and the Natural Science Foundation of Shaanxi Province, China (Grant No. 2015JQ4100).Received Date:19 May 2016
Accepted Date:18 June 2016
Published Online:05 October 2016
Abstract:Biological aerosols which could cause diseases of human beings, animals and plants, are living particles suspended in the atmosphere. Ultraviolet laser induced fluorescence has been developed as a standard technique used to discriminate between biological and non-biological particles. As an effective tool of remote sensing, fluorescence lidar is capable of detecting concentration of biological aerosols with high spatial and temporal resolutions. Intrinsic fluorescence, one of the most important characteristics of biological aerosols, has quite a large effect on the performances of fluorescence lidar. To investigate the effects of intrinsic fluorescence on biological aerosols, we design an ultraviolet laser induced fluorescence lidar at an excited wavelength of 266 nm, with a repetition rate of 10 Hz. Fluorescence signals are collected by a Cassegrain telescope with a diameter of 254 mm, in which fluorescence spectra of 300-800 nm are mainly considered. A spectrograph and a multichannel photomultiplier tube (PMT) array detector are employed to achieve the fine separation and highefficiency detection of fluorescence signals. According to the present configuration, we perform a series of simulations to estimate the measurement range and the concentration resolution of biological aerosols, with a certain pulse energy. With a relative error less than 10%, theoretical analysis shows that designed fluorescence lidar is able to detect the biological aerosols within a range of 1.5 km at a concentration of 1000 particles·L-1. When the detection distance enlarges to 2.1 km, detectable wavelength range is limited to 300-310 nm. In addition, the lidar is capable of identifying minimum concentrations of biological aerosols with 2 particles·L-1 and 4 particles·L-1 at fluorescence wavelengths of 350 nm and 600 nm, respectively, where the induced pulse energy is set to be 60 mJ and detected range 0.1 km. With setting energies of 40 mJ and 20 mJ, minimum concentrations of biological aerosols decrease to 3 particles·L-1 and 6 particles·L-1, respectively, at a fluorescence wavelength of 350 nm. The relative error of minimum concentration resolution is about 2 particles·L-1, increasing rapidly with range. For a fluorescence wavelength of 600 nm, both the minimum concentration and the relative error show relatively high values, 5 particles·L-1 at 40 mJ and 10 particles·L-1 at 20 mJ, where the relative errors are found to be 2 particles·L-1 and 4 particles·L-1, respectively. The results prove that a shorter intrinsic fluorescence wavelength has a better effect on biological aerosol measurement. We believe that a proper intrinsic fluorescence wavelength will further improve the detection accuracy of biological aerosols.
Keywords: biological aerosols/
intrinsic fluorescence/
lidar/
concentration resolution