删除或更新信息,请邮件至freekaoyan#163.com(#换成@)

成人标准BMI双低剂量CTE图像质量控制研究

本站小编 Free考研考试/2024-01-27

张晓金,
张虎,
谢钊,
吴波,
高琴,
汪建文,
芜湖市第二人民医院 医学影像科, 安徽 芜湖 241000

基金项目: 芜湖市第二人民医院院内科研项目(2019D01;2020C12)


详细信息 作者简介: 张晓金(1982-), 女, 主治医师。E-mail:252394498@qq.com






通讯作者: 汪建文, 主任医师, 教授。E-mail:wjw2288@163.com 中图分类号: R445.3


目的探讨成人标准BMI低辐射剂量和低碘对比剂使用量下CT小肠造影(CT enterography,CTE)图像质量控制的可行性。方法将60例CTE患者随机分为双低剂量扫描组(A组,n=30)和常规扫描组(B组,n=30),A组扫描采用100 kV管电压,注射65 mL碘对比剂实现双低剂量扫描,B组采用120 kV管电压,注射85 mL碘对比剂。比较图像噪声、信噪比(SNR)和对比噪声比(CNR)组间差异。两名腹部亚专科医师独立对三期图像进行主观评分(1~5分),Kappa检验操作者间的一致性,并采用Wilcoxon秩和检验评估图像质量主观评分。小肠肿瘤性病变、炎症性病变检出率比较采用χ2检验。结果图像噪声:A组>B组(P < 0.05);图像质量客观指标中,平扫(SNR十二指肠、SNR空肠)、动脉期(SNR小肠、CNR十二指肠、CNR空肠)及静脉期(SNR小肠、SNR肠系膜上静脉、CNR小肠及CNR肠系膜上静脉)A组低于B组,差异有统计学意义(P < 0.05)。图像质量主观评分均≥3分,操作者间呈中高度一致,三期图像A、B两组间主观评分结果均无显著性差异(P>0.05)。对小肠肿瘤性病变、炎症性病变检出率两组间亦无统计学差异(P>0.05)。结论成人标准BMI双低剂量CTE扫描不仅降低了辐射剂量还减少了碘对比剂使用量,虽然图像噪声有所增加,部分图像质量有所下降,但均不影响做出诊断。
关键词: 体层摄影术/
CT小肠造影/
辐射剂量/
图像质量/
噪声


ObjectiveTo investigate the feasibility of image quality control of CT enterography (CTE) in adults with BMI standard under the condition of low radiation dose and low iodine contrast agent.MethodsTotally 60 patients with CTE were divided into two groups randomly, including Double low dose scanning group (group A, n=30) and Routine group (group B, n=30). In group A, the scanning tube voltage was set as 100 kV and we use 65 mL iodine contrast agent for each patient to fulfill double low-dose. In group B, the scanning tube voltage was set as 120 kV and we use 85 mL iodine contrast agent for each patient. The image noise, Signal-to-noise ratio (SNR) and contrast noise ratio (CNR) were compared between the groups. Two abdominal subspecialists scored the three-stage images independently and subjectively (1-5 points). Kappa test was used to check the consistency among operators, and Wilcoxon rank sum test was used to evaluate the subjective image quality score. χ2-test was used in the diagnosis of small intestinal tumor and inflammatory lesions.ResultsThe image noise of group A was significantly higher than that of group B (P < 0.05). In the objective evaluation of image quality, there were statistically significant differences between groups A and B (P < 0.05) for plain scan (SNR duodenum, SNR jejunum), arterial phase (SNR small intestine, CNR duodenum, CNR jejunum) and venous phase (SNR small intestine, SNR superior mesenteric vein, CNR small intestine and CNR superior mesenteric vein). The subjective scores of all images were≥3, and the operators were consistent in a medium to high degree. There was no significant difference in subjective scores between two groups (P>0.05). There was no detection rate difference between two group diagnosis of small intestinal tumor and inflammatory lesions (P>0.05).ConclusionThe double low dose CTE scan of adult standard BMI can not only reduce the radiation dose, but also the iodine contrast agent. Although the image noise has increased and some image quality has decreased, it does not affect the diagnosis.
Keywords:tomography/
CT enterography(CTE)/
radiation dose/
image quality/
noise

PDF全文下载地址:

https://journal.dmu.edu.cn/data/article/export-pdf?id=dlykdxxb_20200606
相关话题/

  • 领限时大额优惠券,享本站正版考研考试资料!
    大额优惠券
    优惠券领取后72小时内有效,10万种最新考研考试考证类电子打印资料任你选。涵盖全国500余所院校考研专业课、200多种职业资格考试、1100多种经典教材,产品类型包含电子书、题库、全套资料以及视频,无论您是考研复习、考证刷题,还是考前冲刺等,不同类型的产品可满足您学习上的不同需求。 ...
    本站小编 Free壹佰分学习网 2022-09-19